首页 / 产品目录 / 频谱分析仪 / RSA518A

RSA518A

便携实时频谱分析仪 · 全新仪器销售
品牌:TEKTRONIX | 类别:频谱分析仪

18 GHz 频率覆盖,雷达与卫星链路外场测试的高频便携方案。

简介
RSA500
详细参数
规格
The RSA500A Series USB spectrum analyzers offer high performance portable
spectrum analysis in a rugged battery-powered package.
capture and vector analysis
High speed full-span sweeps (70 GHz/s) for fast setup and discovery
Standard GPS/GLONASS/Beidou receiver for mapping
Optional tracking generator for gain/loss, antenna and cable measurements
DataVu-PC software enables multi-unit recording in variable bandwidths
Mil-Std 28800 Class 2 environmental, shock and vibration specifications for
use in harsh conditions
Internal battery for extended field operations
SignalVu-PC software offers real time signal processing with DPX®
Spectrum/Spectrogram to minimize time spent on transient and
interference hunting
Time qualified triggers enable capture of events at desired pulse widths,
ideal for capturing dynamic test environments
Frequency mask triggers facilitate the definition of a spectrum mask to
capture events or signal anomalies based on their frequency and amplitude
DPX density trigger allows you to analyze and measure infrequent or
elusive RF events by defining a spectrum measurement box, based on how
frequently the instrument detects RF power within this box it can trigger to
capture the signal
EMC/EMI pre-compliance and troubleshooting - CISPR detectors,
predefined standards, limit lines, easy accessory setup, ambient capture,
failure analysis, and report generation
15 μs minimum signal duration with 100% probability of intercept ensure
you see problems first time, every time
Signal analysis performance improves by pairing the USB RSA500A with
Applications
General-purpose spectrum analysis
Radio network installation and maintenance
Spectrum operations
Radiation hazard (RADHAZ) testing
Emissions control (EMCON) monitoring
Signal intelligence (SIGINT) monitoring
The RSA500 Series saves you time and helps you
succeed
The RSA500 Series was built to bring real-time spectrum analysis to solving
the problems of spectrum managers, interference hunters and network
maintenance personnel who need to track down hard to find interferers,
maintain RF networks and keep records of their efforts. The heart of the
system is the USB-based RF spectrum analyzer that captures 40 MHz real-time
bandwidths with great fidelity in harsh environments. With 70 dB spurious free
dynamic range and frequency coverage to 18.0 GHz, all signals of interest can
be examined with high confidence in your measurement results. The USB form
factor moves the weight of the instrument off of your hands, and replaces it wit
a lightweight Windows tablet or laptop. Holding a light PC instead of a heavy
spectrum analyzer means you can move faster, for longer, and get your work
done faster.
The optional tracking generator enables gain/loss measurements for quick tests
of filters, duplexers and other network elements, and you can add cable and
antenna measurements of VSWR, return loss, distance to fault and cable loss
as needed.
SignalVu-PC™ software and an API for deep
analysis and fast programmatic interaction
The RSA500 Series operates with SignalVu-PC, a powerful program used as
the basis of Tek’s traditional spectrum analyzers. SignalVu-PC offers a deep
analysis capability previously unavailable in high performance battery-operated
solutions. Real-time processing of the DPX® spectrum/spectrogram is enabled
in your PC, further reducing the cost of hardware. Customers who need
programmatic access to the instrument can choose either the SignalVu-PC
programmatic interface or use the included Application Programming Interface
(API) that provides a rich set of commands and measurements directly. The
API supports simultaneous control of up to four devices and is compatible with
Spectrum Analyzer
RSA500A Series Portable Spectrum Analyzer Datasheet
both Windows and Linux operating systems, enabling flexible, and scalable
deployments. Basic functionality of the free SignalVu-PC program is far from
basic. Base version measurements are shown below.
The RSA500A combined with SignalVu-PC offers advanced
field measurements
With 40 MHz of real-time bandwidth, the unique DPX® spectrum/spectrogram
shows you every instance of an interfering or unknown signal, even down to
15 μs in duration. The following image shows a WLAN transmission (green and
orange), and the narrow signals that repeat across the screen are the Bluetooth
access probe. The spectrogram (upper part of the screen) clearly separates
these signals in time to show any signal collisions.
Advanced triggers
SignalVu's advanced triggers simplify the task of acquiring pulsed, transient, o
unexpected RF signals, and elusive over-the-air RF signals in the field. Use the
time qualified trigger to specify the duration of a pulse or signal event to tri
an acquisition.
Enable the DPX density trigger to activate a capture only when a signal appears
in a certain spectrum area with a specific amount of power and duration.
Define a frequency mask trigger to capture when signals appear inside or
outside a predefined area.
DPX density trigger_threshold
support of Enhanced Data Rate
P25 analysis of phase 1 and phase 2 signals
WLAN analysis of 802.11a/b/g/j/p, 802.11n, 802.11ac
LTE™ FDD and TDD Base Station (eNB) Cell ID and RF measurements
Pulse analysis
AM/FM/PM/Direct Audio Measurement including SINAD, and THD
Playback of recorded files, including complete analysis in all domains
Signal classification and survey
Any of these licenses above enable SignalVu's advanced triggering capabilities:
Time qualified, DPX density, and Frequency mask triggers.
See the separate SignalVu-PC data sheet for complete details and ordering
information. Selected applications are illustrated below.
EMC/EMI
EMI pre-compliance and diagnostic measurements are easy with the instrument
and SignalVu-PC. Transducer, antenna, preamplifier, and cable gain/loss
can be entered and stored in correction files, and the standard spurious
measurement feature of SignalVu-PC can be used to establish limit lines for
your test. The following illustration shows a test from 30 MHz to 960 MHz
against the FCC Part 15 Class A limit shown shaded. The blue trace is the
capture of Ambient. Violations are recorded in the results table below the graph
CISPR quasi peak and average detectors can be added with option SVQP.
The EMC pre-compliance solution can be added with option EMCVU. It
supports many predefined limit lines. It also adds a wizard for easy setup of
recommended antennas, LISN, and other EMC accessories with a one-button
push. When using the new EMC-EMI display, you can accelerate the test
by applying the time consuming quasi peak only on failures. This display
also provides a push-button ambient measurement. The Inspect tool lets you
measure frequencies of interest locally, removing the need for scanning.
Bluetooth
Two new options have been added to help with Bluetooth SIG standardbase
transmitter RF measurements in the time, frequency and modulation domains.
Option SV27 supports Basic Rate and Low Energy Transmitter measurements
defined by RF.TS.4.2.0 and RF-PHY.TS.4.2.0 Test Specification. It also
demodulates and provides symbol information for Enhanced Data Rate
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
packets. Option SV31 supports Bluetooth 5 standards (LE 1M, LE 2M, LE
Coded) and measurements defined in the core specification. Both options also
decode the physical layer data that is transmitted and color-encode the fields o
packet in the symbol table for clear identification.
Pass/Fail results are provided with customizable limits. Measurement below
shows deviation vs time, frequency offset and drift and a measurement
summary with Pass/Fail results.
APCO 25
SignalVu-PC application SV26 enables quick, standards-based transmitter
health checks on APCO P25 signals. The following image shows a Phase
II HCPM signal being monitored for anomalies with the spectrogram while
performing transmitter power, modulation, and frequency measurements to the
TIA-102 standards specification.
LTE
Application SV28 enables the following LTE base station transmitter
measurements:
Reference Signal (RS) Power
The measurements follow the definition in 3GPP TS Version 12.5 and
support all base station categories, including picocells and femtocells. Pass/Fa
information is reported and all channel bandwidths are supported.
The Cell ID preset displays the Primary Synchronization Signal (PSS) and the
Secondary Synchronization Signal (SSS) in a Constellation diagram. It also
provides Frequency Error.
The illustration below shows spectral monitoring with the spectrogram display
combined with a Cell ID/Constellation, Spectrum Emission Mask and ACLR
measurements.
Signal survey/classification
Application SV54 enables expert systems guidance to aid the user in classifying
signals. You can quickly create a spectral region of interest, enabling users to
identify and sort signals efficiently. The spectral profile mask, when overlaid
on top of a trace, provides signal shape guidance while frequency, bandwidth,
and channel number are displayed allowing for fast classification. WLAN, GSM,
W-CDMA, CDMA, Bluetooth standard and enhanced data rate, LTE FDD and
TDD, ATSC and other signals can be quickly and simply identified. Databases
can be imported from your H500/RSA2500 signal database library for easy
transition to the new software base.
A typical signal survey is show below. The survey is of a portion of the TV
broadcast band, and seven regions have been declared as either Permitted,
Not Classified, Unknown, or Unauthorized, as indicated by the color bars for
each region. In the detail illustration, a single region has been selected, and
since we have declared this to be an ATSC video signal, the spectrum mask for
the ATSC signal is shown overlaid in the region. The signal is a close match to
the spectrum mask, including the vestigial carrier at the lower side of the sign
which is the characteristic of ATSC broadcasts.
Return loss/VSWR, distance to fault, cable loss
Perform maintenance and troubleshooting tasks with ease. When equipped
with the option 04 tracking generator, the RSA500A Series with application
license SV60xx-SVPC makes one-port measurements on cables, devices and
antennas.
Return loss vs distance for a cable with an inserted barrel and an extension cab
point at M2 (17.638 m, MR) is the barrel connector and the point marked by M1 at
m is the end of the cable.
Return loss of a bandpass filter measured from 700 MHz to 2.6 GHz. Markers have
been placed a 1.48 GHz (-34.4 dB return loss) and at 1.73 GHz (-11.68 dB return
indicating the best and worse match in the passband of the filter.
Playback
Application SV56, playback of recorded signals, can reduce hours of watching
and waiting for a spectral violation to minutes at your desk reviewing recorded
data.
Recording length is limited only by storage media size, and recording is a basic
feature included in SignalVu-PC. SignalVu-PC application SV56 (Playback)
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
allows for complete analysis by all SignalVu-PC measurements, including
DPX Spectrogram. Minimum signal duration specifications are maintained
during playback. AM/FM audio demodulation can be performed. Variable
span, resolution bandwidth, analysis length, and bandwidth are all available.
Frequency mask testing can be performed on recorded signals, with actions on
mask violation including beep, stop, save trace, save picture, and save data.
Portions of the playback can be selected and looped for repeat examination of
signals of interest. Playback can be skip-free, or time gaps can be inserted to
reduce review time.
Clock time of the recording is displayed in the spectrogram markers for
correlation to real world events. In the illustration below, the FM band is bein
replayed, with a mask applied to detect spectral violations, simultaneous with
listening to the FM signal at the center frequency of 92.3 MHz.
DataVu-PC for multi-instrument recording and
analysis of large recordings
DataVu-PC software can control two spectrum analyzers simultaneously with
independent settings. This allows you to monitor a wide span, while recording at
up to 40 MHz bandwidth at any frequency in the range of the instrument. Once
recorded, DataVu-PC can find and mark signals of interest based on amplitude
and frequency-mask characteristics, eliminating the need for manual inspection
of long recordings. Pulse measurements are available on up to 2,000,000
pulses.
Instrument controller for USB spectrum
analyzers
For field operations, a complete solution requires a windows tablet or
laptop for instrument operation, record keeping and communication. Tektronix
recommends Panasonic rugged computers for controlling the RSA500 Series
and as a standalone unit.
Panasonic rugged computers are sold separately and are available for
purchase from Panasonic at connect.na.panasonic.com/toughbook/rugged-
computers and a variety of third party vendors.
Recommended specifications, instrument controller
Windows 10 or Windows 11 Pro 64-bit operating system
Intel(R) CoreTM i5-6300U vProTM 2.4-3.0 GHz Processor
8 GB RAM
256 GB Solid State Drive
10.1" (25.6 cm) Daylight-readable screen
10-point Multi Touch + Digitizer screen plus included pen interface
USB 3.0 + HDMI Ports, 2nd USB Port
Wi-Fi, Bluetooth® and 4G LTE Multi Carrier Mobile Broadband with Satellite
GPS
MIL-STD-810G certified (4' drop, shock, vibration, rain, dust, sand,
altitude, freeze/thaw, high/low temperature, temperature shock, humidity,
and explosive atmosphere)
IP65 certified sealed all-weather design
Integrated microphone and speaker
On-screen and button volume and mute controls
Integrated battery backup for hot-swap of battery packs
Three year warranty with business class support (provided by Panasonic in
your region)
Smart antenna for interference hunting
Tektronix recommends the Alaris smart antenna (DF-A0047) with
built-in USB compass for direction finding and interference
hunting applications. Full details on the antenna are
available from Alaris at usa.alaris.tech/product?i=124&prodCode=DF-
A0047&name=Handheld%20Direction%20Finding%20Antenna. A summary of
features and specifications is shown below.
Frequency Range: 20 MHz – 8.5 GHz
9 kHz-20 MHz extension available(0.3m loop antenna), contact Alaris.
Trigger control for one-hand operation with functions for:
Band switch
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Standard armrest extension for ease in long interference hunting sessions
Transit case available
Alaris direction-finding smart antenna.
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Phase-stabilized cables from Tektronix for cable and antenna measurements
Antennas for interference hunting
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Frequency range
RSA503A
9 kHz to 3 GHz
RSA507A
9 kHz to 7.5 GHz
RSA513A
9 kHz to 13.6 GHz
RSA518A
9 kHz to 18.0 GHz
accuracy
±(RE × MF + 0.001 × Span) Hz
RE: Reference Frequency Error
MF: Marker Frequency [Hz]
Reference frequency accuracy
Initial accuracy at Cal (30 min
warm-up)
±1 x 10-6
First year aging, typical
±1 x 10-6 (One year)
Cumulative error (Initial
accuracy + temperature +
aging), typical
3 x 10-6 (One year)
frequency
Every 1 MHz from 1 to 20 MHz plus the following: 1.2288 MHz, 2.048 MHz, 2.4576 M
13 MHz, and 19.6608 MHz.
The spurious level on the input signal must be less than -80 dBc within 100 kHz
GNSS
Accuracy, when locked to GNSS 1
±0.025 ppm 2
GNSS Trained Accuracy, when
GNSS antenna is disconnected 1, 3
±0.025 ppm 4
±0.08 ppm 5
1 Tested using GPS system.
2 For use to a stability of ±0.025ppm, the unit should be powered on continuousl
3 For 24 hours continuous operation within temperature limits (see footnotes 5 a
mode beyond 24 hours since last training.
4 For less than 3 °C ambient temperature change after training.
5 For less than 10 °C ambient temperature change after training.
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
RF input impedance
50 Ω
RF VSWR (RF Attn = 20 dB),
typical
< 1.2 (10 MHz to 3 GHz)
< 1.5 (>3 GHz to 7.5 GHz)
<1.9 (>7.5 GHz to 18 GHz)
RF VSWR preamp ON,
RSA503A and RSA507A,
Maximum safe input power
+33 dBm (RF input, 10 MHz to 18.0 GHz, RF Attn ≥ 20 dB)
+13 dBm (RF input, 9 kHz to 10 MHz, RF Attn ≥ 20 dB)
+20 dBm (RF input, RF Attn < 20 dB)
(Preamp On)
+33 dBm (RF input, 10 MHz to 18.0 GHz, RF Attn ≥ 20 dB)
+13 dBm (RF input, 9 kHz to 10 MHz, RF Attn ≥ 20 dB)
+20 dBm (RF input, RF Attn < 20 dB)
power
+30 dBm (RF input, ≥ 10 MHz to Fmax, RF ATT Auto)
+20 dBm (RF input, < 10 MHz, RF ATT Auto)
Sweep speed
Full span sweep speed, typical
mean 6
70 GHz/sec (RBW = 1 MHz)
60 GHz/sec (RBW = 100 kHz)
15.7 GHz/sec (RBW = 10 kHz)
1.7 GHz/sec (RBW = 1 kHz)
Reference level setting range
-170 dBm to +40 dBm, 0.1 dB step, (Standard RF input)
6 Measured using a Dell Latitude E5540, i7, Windows®7 Pro. Spectrum display is o
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Frequency response at 18
℃ to 28 ℃ (At 10 dB RF
Center frequency range
18 ⁰C to 28 ⁰C
9 kHz ≤ 3.0 GHz
±0.8 dB
>3 to 7.5 GHz (RSA507A)
±1.5 dB
>7.5 GHz to 13.6 GHz (RSA513A/RSA518A)
±1.55 dB
>13.6 GHz to 18.0 GHz (RSA518A)
±1.55 dB
Amplitude Accuracy at all
center frequencies - Preamp on
(18 ℃ to 28 ℃ , 10 dB RF
Preamp gain
27 dB at 2 GHz
21 dB at 6 GHz (RSA507A)
25 dB at 10 GHz (RSA513A)
25 dB at 15 GHz (RSA518A)
Channel response (amplitude and phase deviation), typical
For these specifications, use a flat top window for maximum CW amplitude verific
Span
Amplitude flatness, typical
Amplitude flatness, RMS,
GHz
≤20 MHz
±0.10 dB
0.08 dB
0.3°
>4 GHz to 7.5
Trigger
Trigger/Sync input, typical
Voltage range: TTL, 0.0 V to 5.0 V
Trigger level (Schmitt trigger):
Positive-going threshold voltage: 1.6 V min, 2.1 V max
Negative-going threshold voltage: 1.0 V min., 1.35 V max
Impedance: 10 k ohms with schottky clamps to 0 V, +3.4 V
DPX density (Host)
External trigger timing uncertainty
>20 MHz to 40 MHz acquisition bandwidth: ±250 ns
Uncertainty increases as acquisition bandwidth is decreased.
Power trigger
Power trigger, typical
Range: 0 dB to -50 dB from reference level, for trigger levels >30 dB above the
Type: Rising or falling edge
Trigger re-arm time: ≤100 μsec
uncertainty
>20 MHz to 40 MHz acquisition bandwidth: ±250 ns
Uncertainty increases as acquisition bandwidth is decreased.
Power trigger level accuracy
±1.5 dB for CW signal at tuned center frequency for trigger levels >30 dB above
This specification is in addition to the overall amplitude accuracy uncertainty
range
0 to -80 dB from reference level
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Noise and distortion
3rd Order IM intercept (TOI)
+14 dBm at 2.130 GHz (RSA503A/RSA507A)
+12 dBm at 2.130 GHz (RSA513A/RSA518A)
3rd Order IM intercept (TOI),
Preamp off, typical
+10 dBm (9 kHz to 25 MHz, RSA503A, RSA507A)
+17 dBm (9 kHz to 25 MHz, RSA513A, RSA517A)
+15 dBm (25 MHz to 3 GHz)
+15 dBm (3 GHz to 4 GHz, RSA507A )
+10 dBm (4 GHz to 7.5 GHz, RSA507A)
+15 dBm (7.5 GHz to Max CF GHz, RSA513A/RSA518A)
Preamp on, typical
-20 dBm (9 kHz to 25 MHz)
-15 dBm (25 MHz to 3 GHz)
-15 dBm (3 GHz to 4 GHz, RSA507A)
-20 dBm (4 GHz to 7.5 GHz, RSA507A)
-15 dBm (7.5 GHz to Max CF, RSA513A/RSA518A)
3rd Order Inter-modulation
distortion
-74 dBc at 2.130 GHz (RSA503A/RSA507A)
-78 dBc at 2.130 GHz (RSA513A/RSA518A)
Each signal level -25 dBm at the RF input. 2 MHz tone separation. Attenuator = 0
3rd Order inter-modulation distortion
Preamp off, typical
< -70 dBc (10 kHz to 25 MHz)
< -80 dBc (25 MHz to 3 GHz)
< -80 dBc (3 GHz to 4 GHz, RSA507A)
< -70 dBc (4 GHz to 7.5 GHz, RSA507A)
< -80 dBc (7.5 GHz to Max CF, RSA513A/RSA518A)
Each signal level -25 dBm at the RF input. 2 MHz tone separation. Attenuator = 0
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Preamp on, typical
< -70 dBc (9 kHz to 25 MHz)
< -80 dBc (25 MHz to 3 GHz)
< -80 dBc (3 GHz to 4 GHz, RSA507A)
< -70 dBc (4 GHz to 7.5GHz, RSA507A)
< -80 dBc (7.5 GHz to Max CF, RSA513A/RSA518A)
Each signal level -55 dBm at the RF input. 2 MHz tone separation. Attenuator = 0
2nd Harmonic distortion, typical
2nd Harmonic distortion
< -75 dBc (40 MHz to 1.5 GHz)
< -75 dBc (1.5 GHz to 3.75 GHz, RSA507A)
<-75 dBc (3.75 GHz to 6.8 GHz, RSA513A)
<-75 dBc (6.8 GHz to 9 GHz, RSA518A)
2nd Harmonic distortion,
Preamp on
< - 60 dBc (40 MHz to 15.9 GHz), input frequency
2nd Harmonic distortion intercept
(SHI)
+35 dBm (40 MHz to 1.5 GHz)
+35 dBm (1.5 GHz to 9 GHz)
2nd Harmonic distortion intercept
(SHI), Preamp on
+5 dBm (40 MHz to 15.9 GHz), input frequency
(DANL)
(Normalized to 1 Hz RBW, with log-average detector)
For the RSA503A and RSA507A:
Offset
10 kHz
100 kHz
1 MHz
1 GHz CF
-94 dBc/Hz
-94 dBc/Hz
-116 dBc/Hz
10 MHz, typical (RSA503A, RSA507A)
-120 dBc/Hz
-124 dBc/Hz
-124 dBc/Hz
1 GHz CF (typical)
-97 dBc/Hz
-98 dBc/Hz
-121 dBc/Hz
2 GHz CF (typical)
-96 dBc/Hz
-97 dBc/Hz
-120 dBc/Hz
6 GHz CF, typical (RSA507A)
-94 dBc/Hz
-96 dBc/Hz
-120 dBc/Hz
10 GHz, typical (RSA513A, RSA518A)
-89 dBc/Hz
-90 dBc/Hz
-113 dBc/Hz
15 GHz, typical (RSA513A, RSA518A)
-86 dBc/Hz
-87 dBc/Hz
-110 dBc/Hz
kHz)
<-75 dBm (500 kHz to 60 MHz), typical
< -85 dBm (>60 MHz to 80 MHz), typical
<-100 dBm (>80 MHz to Max CF), typical
(Exceptions: <-90 dBm (13.78 GHz to 13.94 GHz))
(Image suppression)
< -65 dBc (for RSA513/518A) (10 kHz to Max CF, Ref= -20 dBm, Atten = 10 dB, RF i
< -63 dBc (for RSA503A/507A) (10 kHz to Max CF, Ref= -20 dBm, Atten = 10 dB, RF
Spurious response with signal at
Frequency
Span ≤40 MHz, swept spans >40 MHz
1 MHz - 100 MHz
--
-75 dBc
100 MHz - 3 GHz
-72 dBc
-75 dBc
3 GHz - 7.5 GHz (RSA507A)
-72 dBc
-75 dBc
7.5 GHz to 13.6 GHz (RSA513A/RSA518A)
-72 dBc
-75 dBc
Table continued…
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Typical
1 MHz - 100 MHz
-70 dBc
100 MHz - 3 GHz
-70 dBc
3 GHz - 7.5 GHz (RSA507A)
-70 dBc
7.5 GHz - 13.6 GHz (RSA513A/RSA518A)
-64 dBc
13.6 GHz - 18.0 GHz (RSA518A)
-64 dBc
Spurious response with signal at
other than CF, typical
A/D converter
14 bits, 112 Ms/s.
Real-Time IF Acquisition Data
112 Ms/s, 16-bit integer samples.
ACLR
ACLR for 3GPP Down Link, 1 DPCH
(2130 MHz)
-57 dB (Adjacent Channel)
-68 dB w/Noise Correction (Adjacent Channel)
8 This is an input signal at half of the IF frequency.
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
-57 dB (First Alternate Channel)
-69 dB w/Noise Correction (First Adjacent Channel)
ACLR LTE
-58 dB (Adjacent Channel)
-61 dB w/Noise Correction (Adjacent Channel)
-61 dB (First Alternate Channel)
-63 dB w/Noise Correction (First Adjacent Channel)
GPS antenna power
3 V, 100 mA maximum
Time to first fix, maximum
Lock time ranges from 2 sec (hot) to 46 sec (cold start).
-130 dBm input signal power.
Horizontal position accuracy
GPS: 2.6 m
Glonass: 2.6 m
BeiDou: 10.2 m
GPS + Glonass: 2.6 m
GPS + BeiDou: 2.6 m
Test conditions: 24 hr. static, -130 dBm, full power
Tracking generator (Option 04)
Tracking Generator (Option 04)
Reflection
9 kHz - 3.0 GHz (RSA503A)
9 kHz - 7.5 GHz (RSA507A/513A/518A)
Transmission
10 MHz to 3 GHz (RSA503)
10 MHz to 7.5 GHz (RSA507A/513A/518A)
Sweep speed, typical mean
0.192 sec/sweep, 101 points, 50 kHz RBW, 980 to 1020 MHz sweep (1.9 mS per point
i7, Windows®7 Pro. Transmission Gain display is only measurement on screen.
Harmonics
< -22 dBc, ≥20 MHz
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Non-harmonic spurious
< -30 dBc; spurious < 2 GHz from TG output frequency
< -25 dBc; spurious ≥ 2 GHz from TG output frequency
Reverse power without damage 40 Vdc, +20 dBm RF
SignalVu-PC standard measurements and performance
Measurements included.
Spectrum analyzer
Spans from 1 kHz to 18.0 GHz
Three traces plus math and spectrogram trace
Five markers with power, relative power, integrated power, power density and
DPX Spectrum/Spectrogram
Real time display of spectrum with 100% probability of intercept of up to 15 μse
signals in up to 40 MHz span
Amplitude, frequency, phase vs. time,
RF I and Q vs. time
Basic vector analysis functions
Signal recording
Record 40 MHz bandwidth gap-free in .r3f file format for re-analysis in all
domains including real time spectrum analysis (requires option SV56 installed
Analog modulation analysis
AM, FM, PM analysis
Measures key AM, FM, PM parameters
Spurious measurement
User-defined limit lines and regions provide automatic spectrum violation testin
across the entire range of the instrument. Four traces can be saved and recalled
CISPR Quasi-Peak and Average detectors available with option SVQP.
Maximum span
40 MHz real-time
9 kHz - 3 GHz swept (RSA503A)
9 kHz - 7.5 GHz swept (RSA507A)
9 kHz - 13.6 GHz swept (RSA513A)
9 kHz - 18.0 GHz swept (RSA518A)
Maximum acquisition time
2.0 s
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
SignalVu-PC standard measurements and performance
Tuning Tables
Tables that present frequency selection in the form of standards-based channels
Cellular standards families: AMPS, NADC, NMT-450, PDC, GSM, CDMA, CDMA-2000, 1xE
LTE, WiMax
Unlicensed short range: 802.11a/b/j/g/p/n/ac, Bluetooth
Cordless phone: DECT, PHS
Broadcast: AM, FM, ATSC, DVBT/H, NTSC
Mobile radio, pagers, other: GMRS/FRS, iDEN, FLEX, P25, PWT, SMR, WiMax
Spectrum processing rate
(RBW = auto, trace length 801)
≤10,000 spectrums per second
DPX Spectrogram minimum
time resolution 9
1 ms
≤10,000 per second (span independent)
Minimum signal duration for
100% probability of intercept
(POI), typical 10
15 μs up to 40 MHz span
Trace detection
+Peak, -Peak, Average(VRMS)
Trace length, memory depth
801 (60,000 traces)
2401 (20,000 traces)
4001 (12,000 traces)
CISPR Quasi Peak and Average
9 Due to the non-deterministic execution time of programs running under the Micr
other processing tasks.
10 Subject to differences in host PC performance and due to the non-deterministi
be met when the host PC is heavily loaded with other processing tasks.
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
span
10 MHz
FM measurements (Mod. index
>0.1)
Carrier Power, Carrier Frequency Error, Audio Frequency, Deviation (+Peak, -Peak
Distortion, S/N, Total Harmonic Distortion, Total Non-harmonic Distortion, Hum a
AM measurements
Carrier Power, Audio Frequency, Modulation Depth (+Peak, -Peak, Peak-Peak/2, RMS
Total Harmonic Distortion, Total Non-harmonic Distortion, Hum and Noise
PM measurements
Carrier Power, Carrier Frequency Error, Audio Frequency, Deviation (+Peak, -Peak
Distortion, S/N, Total Harmonic Distortion, Total Non-harmonic Distortion, Hum a
Audio filters
Low pass, kHz: 0.3, 3, 15, 30, 80, 300, and user-entered up to 0.9 × audio bandw
High pass, Hz: 20, 50, 300, 400, and user-entered up to 0.9 × audio bandwidth
Standard: CCITT, C-Message
De-emphasis (μs): 25, 50, 75, 750, and user-entered
File: User-supplied .TXT or .CSV file of amplitude/frequency pairs. Maximum 1000
frequency accuracy
± 0.2 Hz + (transmitter
frequency × ref. freq.
error)
FM deviation: 5
kHz /100 kHz
Table continued…
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Deviation accuracy
± (1% × (rate +
deviation)+50 Hz)
Rate accuracy
± 0.2 Hz
± 0.2 Hz
± 0.2 Hz
FM deviation: 5 kHz /
100 kHz
Residual THD
0.10%
0.16%
0.1%
FM Deviation: 5 kHz /
100 kHz
Rate: 1 kHz
Residual SINAD
43 dB
56 dB
40 dB
FM deviation 5 kHz
FM deviation 100 kHz
Rate: 1 kHz
APCO P25 Measurements Application (SV26xx-SVPC)
Measurements
RF output power, operating frequency accuracy, modulation emission spectrum, unw
channel power ratio, frequency deviation, modulation fidelity, frequency error,
transmitter power and encoder attack time, transmitter throughput delay, frequen
transient frequency behavior, HCPM transmitter logical channel peak adjacent cha
channel off slot power, HCPM transmitter logical channel power envelope, HCPM tr
cross-correlated markers
Modulation fidelity, typical
C4FM ≤ 1.0%
HCPM ≤ 0.5%
HDQPSK ≤ 0.25%
Input signal level is optimized for best modulation fidelity.
Bluetooth Measurements Application (SV27xx-SVPC and SV31xx-SVPC)
Supported standards
Bluetooth® 4.2 Basic Rate, Bluetooth® 4.2 Low Energy, Bluetooth® 4.2 Enhanced Da
enabled.
typical mean
Supported measurements: Average power, peak power
Level uncertainty: refer to instrument amplitude and flatness specification
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Measurement range: signal level > –70 dBm
Modulation characteristics,
energy)
Deviation range: ±280 kHz
Deviation uncertainty (at 0 dBm):
<2 kHz 11 + instrument frequency uncertainty (basic rate)
<3 kHz 11 + instrument frequency uncertainty (low energy)
Measurement range: Nominal channel frequency ±100 kHz
Carrier Frequency Drift (BR
and LE), typical mean
Supported measurements: Max freq. offset, drift f1- f0, max drift fn-f0, max dri
Measurement uncertainty: <1 kHz + instrument frequency uncertainty
Measurement range: Nominal channel frequency ±100 kHz
In-band emissions (ACPR) (BR
and LE)
Level uncertainty: refer to instrument amplitude and flatness specification
General-purpose digital modulation analysis (SVMxx-SVPC)
Modulation formats
BPSK, QPSK, 8PSK, 16QAM, 32QAM, 64QAM, 128QAM, 256QAM, 1024QAM, π/2DBPSK, DQPSK,
D16PSK, SBPSK, OQPSK, SOQPSK, 16-APSK, 32-APSK, MSK, CPM, 2FSK, 4FSK, 8FSK, 16FS
Vector diagram display format
Symbol/locus display, Frequency Error measurement, Origin Offset measurement
LTE Downlink RF measurements (SV28xx-SVPC)
supported
Adjacent Channel Leakage Ratio (ACLR), Spectrum Emission Mask (SEM), Channel Pow
versus. Time showing Transmitter OFF power for TDD signals and LTE constellation
Signal and Secondary Synchronization Signal with Cell ID, Group ID, Sector ID, R
Error.
Mapping (MAPxx-SVPC)
and setup files)
MapInfo-compatible MIF/MID files
11 At nominal power level of 0 dBm
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Pulse measurements (SVPxx-SVPC)
Measurements (nominal)
Pulse-Ogram™ waterfall display of multiple segmented captures, with amplitude vs
Pulse frequency, Delta Frequency, Average on power, Peak power, Average transmit
time, Repetition interval (seconds), Repetition interval (Hz), Duty factor (%),
Droop (dB), Droop (%), Overshoot (dB), Overshoot (%), Pulse- Ref Pulse frequency
difference, Pulse- Pulse frequency difference, Pulse- Pulse phase difference, RM
RMS phase error, Max phase error, Frequency deviation, Phase deviation, Impulse
Time stamp.
Minimum pulse width for detection,
File playback controls
General: Play, stop, exit playback
Location: Begin/end points of playback settable from 0-100%
Skip: Defined skip size from 73 μs up to 99% of file size
Live rate: Plays back at 1:1 rate to recording time
Loop control: Play once, or loop continuously
Memory requirement
Recording of signals requires storage with write rates of 300 MB/sec. Playback o
with read rates of 300 MB/sec.
WLAN Measurements, 802.11a/b/g/j/p (SV23xx-SVPC)
Standards
EN55011, EN55012, EN55013, EN55014, EN55015, EN55025, EN55032, EN60601, DEF STAN
IEC 61000-6-3, and MIL-STD 461G
Features
EMC-EMI display, Wizard to setup accessories and limit lines, Inspect, Harmonic
Measure Ambient, Report generation, Re-measure Spot
Detectors
+Peak, Avg, Avg (of logs), Avg (VRMS), CISPR QuasiPeak, CISPR Peak, CISPR Averag
+Peak, DEF STAN Avg, DEF STAN Peak
error
Return Loss of 0 to 15 dB: ±0.5 dB
Return Loss of 15 to 25 dB: ±1.5 dB
Return Loss of 25 to 35 dB: ±4.0 dB
Return Loss measurement
error at 14 dB Return Loss
±1.5 dB from 10 MHz to 6.8 GHz
±3.0 dB from 6.8 GHz to 7.5 GHz
12 201 point sweep Measured using a Panasonic Toughpad FZ-G1, Intel® Core™ i5-53
Loss, or Distance-to-Fault display is the only measurement on screen.
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Interference immunity
Return Loss Measurement Error within specifications for the following conditions
+5 dBm interferer power within 800 kHz of measurement point
+5 dBm interferer power more than 800 kHz away from measurement point
(High power test level. Interferer not included in accuracy assessment.)
Distance-to-Fault range
1500 m or 15 dB one-way cable loss capable, user defined
Maximum range is a function of the cable velocity factor and the frequency step
Where:
Vp = Cable velocity factor relative to the speed of light
c = Speed of light (m/s)
Fstart = Sweep start frequency (Hz)
Fstop = Sweep stop frequency (Hz)
N = number of sweep points
Distance-to-Fault resolution
RSA503A, (RG-58Vp=0.66): 0.03 m (User Definable)
RSA507A, (RG-58Vp=0.66): 0.01 m (User Definable)
Minimum resolution is a function of the cable velocity factor and the frequency
RF input
RSA503A/507A: N type, female
RSA513A/518A: N type, female (ships standard with this connector)
RSA513A/518A: Planar Crown, 50 Ω. Users can select this connector instead of the
best fits their applications. (Users can use adapters compatible with the planar
USB Status LED
LED, dual color red/green
LED states:
Steady Red: USB power applied, or resetting
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Steady Green: Initialized, ready for use
Blinking Green: Transferring data to host
Battery Status LED
LED, green
LED states:
Blinking Green: External power connected, charging battery
Off – no external power connected or battery fully charged
Cooling clearance
Bottom, top
25.4 mm ( 1.0 in.)
Sides
25.4 mm (1.0 in.)
Rear: 25.4 mm (1.0 in.)
Voltage range limits
Operation: +12.0 V to +19.95 V
Battery Charging: +17.5 V to +19.95 V
Connector type
2.5 mm male
Center conductor: positive
Outer conductor: negative
AC Adapter Output
18 V ± 5%, 5 A (90 W max)
Center conductor: positive
Outer conductor: negative
Battery operating temperature
Operating (discharge) 13: -10 °C to +45 °C (14 °F to 113 °F) 14
Charging: 0 °C to 45 °C (32 °F to 113 °F)
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Battery storage life
two years at +20 °C (68 °F) nominal
Max storage duration between recharge: 10 months @ +20 °C (68 °F)
Net weight
RSA503A/507A: 2.54 kg (5.6 pounds) without battery 2.99 kg (6.6 pounds) with bat
RSA513A/518A: 3.40 kg (7.5 pounds) without battery 3.85 kg (8.5 pounds) with bat
Without battery installed
Operating: -10 °C to +55 °C (+14 °F to +131 °F)
Non-operating: -51 °C to +71 °C (-60 °F to +160 °F)
With battery installed
Operating (discharge)13 : -10 °C to +45 °C (+14 °F to +113 °F)14
Charging: 0 °C to 45 °C (32 °F to +113 °F)
Without battery Installed
MIL-PRF-28800F Class 2
Operating:
5% to 95±5%RH (relative humidity) in the temperature range of +10 °C to 30 °C (+
5% to 75±5% RH above +30 °C to 40 °C (+86 °F to 104 °F)
5% to 45±5% RH above +40 °C up to +55 °C (+86 °F to +131 °F)
<10 °C (+50 °F) humidity is uncontrolled; non-condensing
With battery Installed
Operating:
5% to 95% RH (relative humidity) in the temperature range of +10 °C to 30 °C (+1
5% to 45% RH above +30 °C to 50 °C (+86 °F to 122 °F)
<10 °C (+50 °F) humidity is uncontrolled; non-condensing
Operating
Up to 5000 m (16,404 ft.)
Non-operating
Up to 15240 m (50,000 ft.)
Exposure
Splash-Proof test, operating
and non-operating
No potential of shock hazard after exposure to non-operating Splash Proof Test p
13 Operation at -10 °C may require turning on the unit at room temperature first
14 Varies per discharge current and heat dissipation characteristics; actual lim
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
Dust resistance test, operating
and non-operating
Test method per IEC529, level IP52, test conditions 13.4 and 13.5.
Salt exposure test, structural
Handling and transit
Bench handling, operating
MIL-PRF-28800F Class 2
Transit drop, non-operating
MIL-PRF-28800F Class 2
Free-Fall drop, non-operating
32 inches
Spectrum Analyzer RSA500A Series Portable Spectrum Analyzer Datasheet
FAQ / 常见问题

问:RSA518A的频率范围是多少?

答:RSA518A 的频率范围为 9 kHz – 18 GHz。以上为官方规格,实际供货配置与选型可让工程师按你的测试需求核对。

问:RSA518A的形态是多少?

答:RSA518A 的形态为 USB 型便携频谱分析仪,坚固电池供电机箱。以上为官方规格,实际供货配置与选型可让工程师按你的测试需求核对。

问:RSA518A的定位是多少?

答:RSA518A 的定位为 现场干扰排查、外场频谱监测、EMC/EMI 预兼容测试。以上为官方规格,实际供货配置与选型可让工程师按你的测试需求核对。

问:RSA518A用在什么射频测试场景?

答:18 GHz 频率覆盖,雷达与卫星链路外场测试的高频便携方案。具体是否匹配你的测试对象,可把需求发给工程师免费核对型号。

问:RSA518A选型关键参数有哪些?

答:建议先看 频率范围(9 kHz – 18 GHz)、形态(USB 型便携频谱分析仪,坚固电池供电机箱) 这几项,再结合你的被测信号/器件类型确认档位。不同子型号配置有差异,选型时让工程师按需求比对最稳妥。

问:RSA518A 是全新原装吗?货期和保修怎么算?

答:全新原装正品、正规渠道供货,序列号可送原厂查验(非翻新、非演示机);常规配置现货或 1~2 周内发货,特殊配置下单前书面确认交期;按厂家政策享受原厂保修。